1
EN
5
Pin assignment
This chapter describes the Cleco Production Tools specific
connectors. Standard plugs are not considered. All con-
nections are short-circuit proof.
X5, X6 – Serial port for additional devices
•
All outputs provide RS232 conforming signals.
•
The inputs allow voltages in the range from -15 V to
+15 V.
-
Voltages < 0.8 V correspond to a zero.
-
Voltages > 2.4 V are interpreted as a one.
-
Open inputs are preset to zero using a pulldown
resistor.
•
The power supply pins are connected directly to the
main board power supply
.
Note
Do not connect or disconnect any device
during operation. Doing so may result in a
system reset.
Pin
RS232-1
X5
1
–
2
RxD
3
TxD
4
–
5
GND
6
–
7
RTS
8
CTS
9
–
X7, X8 – Anybus CC
Optional slots for Anybus CC modules.
X21 – TSnet System Bus Out
Interface port for TSnet cable.
Pin
Signal
1
Tx +
2
Tx -
3
Rx +
4
RX -
5
0 VDC
6
0 VDC
7
+24 VDC
8
+24 VDC
10
RS23-2
9 pin D-Sub male
X6
with screw lock
–
RxD
TxD
–
GND
–
RTS
CTS
–
8 pin M12 circular connector
X-coded
3
2
1
4
8
5
6
7
X22 – ARCNET system bus
The station controller has an integrated bus termination;
therefore, no external termination is necessary.
Pin
Signal
1
N.C.
2
DATA-B
3
GND
4
+5 VDC
5
DATA-A
6
N.C.
7
0 VDC
8
+24 VDC
X23 – Supply
Description
Connector with fuse holder
2-pin, 5 × 20 mm, 16 A slow-
blow
Note
Use plug locking mechanism. See P2361-
JH.
X24 – Tool Cable 30/50E×N... Series
Pin
Signal
1-3
Power
4
PE (functional
ground)
5
Tool bus
X25 – Tool cable 18/48E×E... Series
Pin
Signal
1-3
Power
4
PE
5
Signals
P2300HW | 2019-03
8 pin M12 circular connector
A-coded
5
4
6
3
1
2
8
Output (Sockel)
IEC connector C14
M23 circular connector
5
3
1
2
4
ECTA circular connector
Push-pull
1
4
2
3
5
Apex Tool Group
7