GE UVW8301 Instructions page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION HEIGHT TABLE
Installation Height with Supplied Duct Covers
Possible
Ceiling
Vented Install
Height (ft./in.)
Height (in.)
7' 6"
24
7' 7"
24-25
7' 8"
24-26
7' 9"
24-27
7' 10"
24-28
7' 11"
24-29
8'
24-30
8' 1"
24-31
8' 2"
24-32
8' 3"
24-33
8' 4"
24-34
8' 5"
24-35
8' 6"
25-36
8' 7"
26-36
8' 8"
27-36
8' 9"
28-36
8' 10"
29-36
8' 11"
30-36
9'
31-36
9' 1"
32-36
9' 2"
33-36
9' 3"
34-36
9' 4"
35-36
9' 5"
36
7/8" min
25-1/8" max
25-3/4"
Hood Body
10" High Ceiling Duct Cover Kit
12
Installation Preparation
Possible
Vented
Install Height
Possible
(Recirculation
Recirculation
Vented Holes
Install
Hidden) (in.)
Height (in.)
24
24-25
24-26
24-27
24-28
24
24-29
24-25
24-30
24-26
24-31
24-27
24-32
24-28
25-33
24-29
26-34
24-30
27-35
24-31
28-36
25-32
29-36
26-33
30-36
27-34
31-36
28-35
32-36
29-36
33-36
30-36
34-36
31-36
35-36
32-36
36
33-36
34-36
35-36
36
*Based on a 36" electric range height.
For gas range, start chart at 92" and subtract 2" for the maximum install height for each block.
Upper
Duct Cover
7/8" min
29-7/16" max
46-7/8"
Lower
Duct Cover
12" High Ceiling Duct Cover Kit
(UX10DC93SS)
Optional High Ceiling Duct
Cover up to 10 ft.
(not included with unit)
Vented and
Ceiling
Recirculation
Height (ft./in.)
Height (in.)
Height (ft./in.)
7' 6"
24
7' 7"
24-25
7' 8"
24-26
7' 9"
24-27
7' 10"
24-28
7' 11"
24-29
8'
24-30
8' 1"
24-31
8' 2"
24-32
8' 3"
24-33
8' 4"
24-34
8' 5"
24-35
8' 6"- 9' 5"
24-36
9' 6"
25-36
9' 7"
26-36
9' 8"
27-36
9' 9"
28-36
9' 10"
29-36
9' 11"
30-36
10'
31-36
10' 1"
32-36
10' 2"
33-36
10' 3"
34-36
10' 4"
35-36
10' 5"
36
Upper
Duct Cover
Lower
Duct Cover
Hood Body
(UX12DC93SS)
Optional High Ceiling Duct
Optional High Ceiling Duct
Cover up to 12 ft.
(not included with unit)
Vented and
Recirculation
Ceiling
Install
Ceiling
Height (in.)
Height (ft./in.)
9' 3"
24
9' 4"
24-25
9' 5"
24-26
9' 6"
24-27
9' 7"
24-28
9' 8"
24-29
9' 9"
24-30
9' 10"
24-31
9' 11"
24-32
10'
24-33
10' 1"
24-34
10' 2"
24-35
10'3"-11'
24-36
11' 1"
24-36
11' 2"
24-36
11' 3"
24-36
11' 4"
24-36
11' 5"
24-36
11' 6"
24-36
11' 7"
24-36
11' 8"
25-36
11' 9"
26-36
11' 10"
27-36
11' 11"
28-36
12'
29-36
7/8" min
46-1/4" max
46-7/8"
14" High Ceiling Duct Cover Kit
(UX14DC93SS)
Cover up to 14 ft.
(not included with unit)
Vented and
Recirculation
Install
Height (in.)
11' 11"
24-36
12'
24-36
12' 1"
24-36
12' 2"
24-36
12' 3"
24-36
12' 4"
24-36
12' 5"
24-36
12' 6"
24-36
12' 7"
24-36
12' 8"
24-36
12' 9"
24-36
12' 10"
24-36
12' 11"
24-36
13'
24-36
13' 1"
25-36
13' 2"
26-36
13' 3"
27-36
13' 4"
28-36
13' 5"
29-36
13' 6"
30-36
13' 7"
31-36
13' 8"
32-36
13' 9"
33-36
13' 10"
34-36
13' 11"
35-36
14"
36
Upper
Duct Cover
Lower
Duct Cover
Hood Body
1' = 0.3 m; 1" = 2.5 cm
29-6324

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Uvw8361

Table des Matières