After Usage; Care And Maintenance - Mesto 3270FO Mode D'emploi

Masquer les pouces Voir aussi pour 3270FO:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
EN
Foaming
Observe the instructions in the section entitled "Safety".
Operate the device only while it is vertical or suspended upright and nearly vertical.
Avoid allowing drops of spray to drift onto areas that are not being treated.
Observe the instructions of the spray product manufacturer!
1. Hang the device over your shoulder. (Fig. 11)
2. Align the foam nozzle to the area to be sprayed with a distance of 50 / 70 cm.
4. Make certain the optimum spraying pressure is set on the piston pressure gauge [7]
(Fig. 10).
+
6. In case the foam width becomes increasingly smaller, pump some more.

After Usage

Observe the instructions in the section entitled "Safety".
Never leave liquid in the device.
1. Pull up the red button on the piston pressure gauge [7] until all excess pressure is
released from the tank. (Fig. 3)
2. Lock the piston rod with handle [9].
3. Unscrew the pump [2] from the tank. (Fig. 6)
Collect and dispose of the residual liquid and the tank according to all applicable
laws, requirements and regulations.
Follow the instructions of the spray product manufacturer!
4. Add water to the tank and spray it out for cleaning.
6. For drying and storing the device, keep the tank [1] and pump [2] separate in a dry
place protected from sunlight and freezing temperatures (Fig. 13)
Clean the protective equipment and yourself every time after usage.

Care and maintenance

Observe the instructions in the section entitled "Safety".
After using the device 50 times or at least once a year:
Unscrew the pump [2] from the tank. (Fig. 6)
Dismantle the pump [2]. (Fig. 14)
Grease the diaphragm [12].
Assemble the pump.
Grease the O-ring [11]
(Fig. 12b)
17
ENGLISH
(Fig. 12a)
-

Publicité