Sauna Operation With Preset Time; Evaporator Operation With Preset Time - Karibu Modern Bio Plug'n'Play Mode D'emploi

Masquer les pouces Voir aussi pour Modern Bio Plug'n'Play:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

7
Sauna operation with preset
time
7.1 Switching on control unit
Switch on control unit in accordance with Chapter 4.1.
7.2 Setting preset time
The time until the heater switches on is set. The mi-
nimum time which can be set is 15 minutes (display
00.15), the maximum time which can be set is 23 hours
and 45 minutes (display 23.45).
1. Press time button 9 and keep depressed.
• The preset time is zeroed and then counts in 15
minute steps.
2. Release time button 9.
• The display 3 shows the selected preset time.
• The preset time is started and the time remaining
in each instance until the heater starts is displayed.
3. Set the desired temperature with the control kno 4.
Mark the desired temperature with a pencil mark,
for example.
The heater is started when the preset time has expired.
If the cabin temperature measured is less than the set
target temperature, the heater is triggered. The control
unit heats up.
If the cabin temperature measured is greater than the
set target temperature, the heater is not triggered.
7.3 Deleting preset time
1. Briefly press the time button 9.
• The preset time is deleted.
7.4 Switching off control unit
Switch off control unit in accordance with Chapter 4.2.
Instructions for use - Figure 5
• 23 •
8
Evaporator operation with pre-
set time
8.1 Switching on control unit
Switch on control unit in accordance with Chapter 4.1.
8.2 Setting preset time
The time until the heater and evaporator switch on is
set. The minimum time which can be set is 15 minutes
(display 00.15), the maximum time which can be set is
23 hours and 45 minutes (display 23.45).
1. Press time button 9 and keep depressed.
• The preset time is zeroed and then counts in 15
minute steps.
2. Release time button 9.
• The display 3 shows the selected preset time.
• The preset time is started and the time remaining
in each instance until the heater starts is displayed.
Evaporator mode only at temperatures below 65°C:
See Chapter 1 operating modes.
3. Set the desired temperature in the range 5 (40°-
65°C) with the control knob 4 and set the desired
evaporator power with the control knob 6. Mark
the desired temperature with a pencil mark, for
example.
After the preset time has expired, the heater and the
evaporator are started. The evaporator power is at-
tained by briefly switching the evaporator on and off.
The time of switch-on and switch-off is dependent on
the power stage set.
8.3 Deleting preset time
1. Briefly press the time button 9.
• The preset time is deleted.
8.4 Switching off the control unit
Switch off the control unit in accordance with Chapter
4.2.