Connecting the heater to the power supply
A method to disconnect all poles from the mains (a circuit
breaker) must be installed on the power circuit before the sauna
controller.
Only a certified electrician is allowed to connect the heater to the
power supply.
The power cable of the heater must meet the requirements of UL
62 in US and CSA 49 in Canada.
It is recommended to connect the unit to the mains without an
earth-leakage circuit breaker.
The maximum current intensity in the cross-sectional area of the
cable and circuit breaker are listed in Table 2.
The cable must be secured to the clamp on the cover screw.
Attention!
It is forbidden to use a non-heat-resistant cable with PVC
isolation as the power cable. The joint box must be waterproof and it
must be located up to 19.7 in (50 cm) from the floor.
Open the cover of the heater's electrical box.
Attach the power cable on the terminal block according to the
circuit diagram.
Close the cover.
Fix the cable on the output with a cable strap.
HIVE 6 kW
HIVE 9 kW
HIVE 10.5 kW
240V 2~
6
L1 L2
HIVE 12 kW
HIVE 15 kW
HIVE 18 kW
L1
L1
L2
L2