NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
MINIMUM CLEARANCE FROM
COMBUSTIBLE MATERIALS
A.Whenoperating,theheatersurfacesareextremelyhot.Keep
sleepingbags,clothing,andallcombustiblematerialsclearof
theheaterbyatleastthedistancesshowninfigure3.
B. WARNING:Toavoidinjuryorpropertydamageneverallow
clothing,tentsorothercombustiblematerialswithin36"of
thefaceoftheheater.Thisheatermustbelocatedatleast
27"abovethefloorlevelwheninuse.Neveroperatethe
heaterwhensleeping.
C. WARNING:Neverdirecttheheatoutputofthisheater
towardanypropanetankwithin20feet.
36
CLEARANCETOCOMBUSTIBLES
BTU/HR.Rating
Model
BTU
FRONT
SIDES
no.
Input
30,000-
MH540T
36,000-
36"
36"
45,000
Figure3
ODOR FADE WARNING
WARNING
Asphyxiation Hazard
•
Donotusethisheaterforheatinghumanliving
quarters.
•
Donotuseinunventilatedareas.
•
Theflowofcombustionandventilationairmust
notbeobstructed.
•
Properventilationairmustbeprovidedto
supportthecombustionairrequirementsofthe
heaterbeingused.
•
Refertothespecificationsectionoftheheater's
manual,heaterdataplate,orcontactthefactory
todeterminecombustionairventilation
requirementsoftheheater.
•
Lackofproperventilationairwillleadto
impropercombustion.
•
Impropercombustioncanleadtocarbon
monoxidepoisoningleadingtoseriousinjuryor
death.Symptomsofcarbonmonoxidepoisoning
canincludeheadaches,dizzinessanddifficulty
inbreathing.
HeatStar |540T Gas-Fired Infra-Red Tank Top Heater
"
48
"
36
"
27
REAR
TOP
BELOW
36"
48"
27"
FUEL GAS ODOR
LP gas and natural gas have man-made odorants added
specifically for detection of fuel gas leaks.
If a gas leak occurs you should be able to smell the fuel
gas. Since Propane (LP) is heavier than air you should smell
for the gas odor low to the floor. ANY GAS ODOR IS YOUR
SIGNAL TO GO INTO IMMEDIATE ACTION!
•Donottakeanyactionthatcouldignitethefuelgas.Donot
operateanyelectricalswitches.Donotpullanypowersupply
orextensioncords.Donotlightmatchesoranyothersource
offlame.Donotuseyourtelephone.
•Geteveryoneoutofthebuildingandawayfromthearea
immediately.
•Closeallpropane(LP)gastankorcylinderfuelsupplyvalves,
orthemainfuelsupplyvalvelocatedatthemeterifyouuse
naturalgas.
•Propane(LP)gasisheavierthanairandmaysettleinlow
areas.Whenyouhavereasontosuspectapropaneleak,keep
outofalllowareas.
•Useyourneighbor'sphoneandcallyourfuelgassupplierand
yourfiredepartment.Donotre-enterthebuildingorarea.
•Stayoutofthebuildingandawayfromtheareauntildeclared
safebythefirefightersandyourfuelgassupplier.
•FINALLY,letthefuelgasservicepersonandthefirefighters
checkforescapedgas.Havethemairoutthebuildingand
areabeforeyoureturn.Properlytrainedservicepeoplemust
repairanyleaks,checkforfurtherleakages,andthenrelight
theapplianceforyou.
ODOR FADING - NO ODOR DETECTED
•Somepeoplecannotsmellwellinwhichcasetheymaynot
beabletosmelltheodoroftheman-madechemicaladdedto
propane(LP)ornaturalgas.Youmustdetermineifyoucan
smelltheodorantinthesefuelgases.
•Learntorecognizetheodorofpropane(LP)gasandnatural
gas.Localpropane(LP)gasdealerswillbemorethanhappy
togiveyouascratchandsniffpamphlet.Useittobecome
familiarwiththefuelgasodor.
•Smokingcandecreaseyourabilitytosmell.Beingaround
anodorforaperiodoftimecanaffectyoursensitivityto
thatparticularodor.Odorspresentinanimalconfinement
buildingscanmaskfuelgasodor.
•The odorant in propane (LP) gas and natural gas is
colorless and the intensity of its odor can fade under
some circumstances.
•Ifthereisanundergroundleak,themovementofgasthrough
thesoilcanfiltertheodorant.
•Propane(LP)gasodormaydifferinintensityatdifferent
levels.SincePropane(LP)gasisheavierthanair,theremaybe
moreodoratlowerlevels.
• Always be sensitive to the slightest gas odor. Ifyou
continuetodetectanygasodor,nomatterhowsmall,treat
itasaseriousleak.Immediatelygointoactionasdiscussed
previously.
4