Remedy of faults

Malfunction
Solenoid valve does not
open
Solenoid valve opens
frequently
7

Maintenance and cleaning

• Check the water level of the pond and the function of the free flowing outlet (with air gap separation)
and overflow regularly several times a year.
• Regularly and several times a year: Check the level sensor for deposits and clean with a brush if
necessary.
7.1

Cleaning the strainer

How to proceed:
 H
1. Shut off the drinking water supply.
2. Unscrew the sealing cap on the strainer.
3. Remove the sieve and clean under running water.
4. Replace the sieve and screw on the sealing cap.
5. Turn on the drinking water supply.
8

Storage/overwintering

The unit is not frost proof. The level sensor and solenoid valve must be removed before the tempera-
ture falls below zero. Clean all parts and check for damage before putting into storage.
9

Spare parts

The use of original parts from OASE ensures
continued safe and reliable operation of the unit.
Please visit our website for spare parts drawings
and spare parts.
10

Disposal

N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the
return system provided for this purpose.
Cause
Power supply interrupted
Current supply to the solenoid valve interrupted
Connection of the level sensor to the level control
unit interrupted
Level sensor transmits incorrect values
Sensitivity of the level sensor too low
Solenoid valve soiled
Solenoid valve defective
Pond is losing water through a leak
Remedy
Check the connection of the level control
unit to the mains
Check the connection of the level control
unit to the solenoid valve
Check the connection of the level control
unit to the level sensor
Check the positioning of the level sensor
Clean the electrodes of the level sensor
Increase the sensitivity setting of the
level sensor
• Clean solenoid valve
• Fit the strainer in front of the solenoid
valve in the drinking water supply
Send solenoid valve to an OASE dealer
for repair
Check pond for leaks
www.oase-livingwater.com/spareparts