Stopping The Engine; Low Oil Level Shutdown System; Section 3 - Maintenance; Maintenance Schedule - Generac GP Série Guide Du Propriétaire

Génératrice portable de 5 000, 5 500 et 6 500 watts
Masquer les pouces Voir aussi pour GP Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Turn engine RUN/STOP switch to
Pull engine CHOKE knob outward to
(Figure 12).
To start engine, firmly grasp the recoil handle and pull slowly until
increased resistance is felt. Pull rapidly up and away.
When engine starts, move choke knob to
engine runs smoothly and then fully into RUN position. If engine
falters, move choke back out to 1/2-CHOKE position until engine
runs smoothly and then to RUN position.
If engine fires, but does not continue to run, move choke lever to
FULL CHOKE and repeat starting instructions.
Figure 12 - Choke Position
IMPORTANT: Do not overload the generator. Also, do not overload
individual panel receptacles. These outlets are protected against
overload with push-to-reset-type circuit breakers. If amperage rating
of any circuit breaker is exceeded, that breaker opens and electrical
output to that receptacle is lost. Read "Don't Overload the Generator"
carefully.

2.9 STOPPING THE ENGINE

Shut off all loads, then unplug the electrical loads from generator
panel receptacles. Never start or stop the engine with electrical
devices plugged in and turned on.
Let engine run at no-load for several minutes to stabilize the
internal temperatures of engine and generator.
Move Run/Stop switch to
Close fuel valve.

2.10 LOW OIL LEVEL SHUTDOWN SYSTEM

The engine is equipped with a low oil level sensor that shuts down the
engine automatically when the oil level drops below a specified level. If
the engine shuts down by itself and the fuel tank has enough gasoline,
check engine oil level.
ON position (Figure 12).
FULL CHOKE position
1/2-CHOKE position until
NOTE:
OFF position.
Section 3 — Maintenance
Portable Generator System
2.10.1 SENSING LOW OIL LEVEL
If the system senses a low oil level during operation, the engine shuts
down. The engine will not run until the oil has been refilled to the
proper level.

3.1 MAINTENANCE SCHEDULE

Follow the calendar intervals. More frequent service is required when
operating in adverse conditions noted below.
Check Oil Level
Change Oil
Check Valve Clearance
Service Air Filter
Replace Spark Plug
*
Change oil and oil filter every month when operating under heavy load or in high
temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air filter parts
if they cannot be adequately cleaned.
*** Check valve clearance and adjust if necessary after first 50 hours of operation and
every 100 hours thereafter.

3.2 PRODUCT SPECIFICATIONS

3.2.1 GENERATOR SPECIFICATIONS
Rated. Power ........................................................................ 5.0/5.5/6.5 kW**
Surge Power ........................................................................ 6.25/6.88/8.0 kW
Rated AC Voltage .............................................................................. 120/240
Rated AC Load
Current @ 240V (5.0/5.5/6.5 kW) ............................ 20.8/22.9/27.1 Amps**
Current @ 120V (5.0/5.5/6.5 kW) ............................ 41.7/45.8/54.2 Amps**
Rated Frequency ............................................................ 60 Hz @ 3600 RPM
Phase ........................................................................................ Single Phase
** Maximum wattage and current are subject to, and limited by, such factors as fuel
Btu content, ambient temperature, altitude, engine condition, etc.. Maximum power
decreases about 3.5% for each 1,000 feet above sea level; and will also decrease
about 1% for each 6° C (10° F) above 16° C (60° F) ambient temperature.
3.2.2 ENGINE SPECIFICATIONS
Displacement ........................................................................................389 cc
Spark Plug Type ....................................NHSP F7RTC or Champion RN9YC
Spark Plug Gap (5.0/6.5 kW) ................ 0.028-0.031 inch or (0.70-0.80 mm)
Gasoline Capacity ................................................................. 6.6 U.S. gallons
Oil Type .......................See Chart in "Before Starting the Generator" Section
Oil Capacity .......................................................................... 1.1 L (1.16 Qts.)
Class II Emission Certified*
* The engine manufacturer must warrant the emission control system for a
period of two years. This warranty coverage is in addition to the warranty
provided by Generac, and may cover the engine even if Generac's warranty
does not.
At Each Use
*Every 100 hours or Every Season
***Every Season
** Every 200 hours or Every Season
Every Season
9
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gp 005688-0Gp 005690-0Gp 005738-0

Table des Matières