Warning
• This Comelit product was designed for use in the creation of security and home automation systems in residential, commercial or industrial settings and
in public buildings or buildings used by the public.
• All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the
indications provided in the manuals / instruction sheets supplied with those products.
• Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
• We advise against running the system wires through the same duct as the power cables (230V or higher).
• Cut off the power supply before carrying out any maintenance procedures.
• To ensure Comelit products are used safely: carefully observe the indications provided in the manuals / instruction sheets and make sure the system
created using Comelit products has not been tampered with / damaged.
• Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in the
manuals / instruction sheets. Any repair work must be carried out: for the products themselves, exclusively by Comelit Group S.p.A., for systems, by
qualified technical personnel.
• Comelit Group S.p.A. does not assume any responsibility for: any usage other than the intended use; non-observance of the indications and warnings
contained in this manual / instruction sheet. Comelit Group S.p.A. nonetheless reserves the right to change the information provided in this manual /
instruction sheet at any time and without prior notice.
SimpleHome module equipped with 2 inputs for the direct connection of 2 control buttons and 2 outputs with 2A solid state relays
allowing control of loads up to 240Vac and a maximum of 500W.
Suitable for control of automated opening such the motors for sunblinds or roller shutters with power consumption up to 500W, or
halogen, LED and compact fluorescent lights.
The module outputs cannot be connected to control panels for rolling shutters with clean (voltage free) contacts
or to appliances which operate in direct current.
Power supply voltage
Consumption
Inputs
TOTAL MAXIMUM LOAD: 2A - 230 Vac!
Outputs
240 Vac cosfi 0.6 motors for automated
openings
230 Vac halogen lamps
240Vac compact fluorescent lamps (CFL)
240 Vac LED lamps:
BUS and power supply
Positioning
Approvals
Operating temperature
Storage temperature
Relative air humidity
Weight
Dimensions
* with access allowed only for support or servicing by qualified personnel.
The address of the module on the SimpleHome BUS must be set using the DIP switches on the module itself. The table below can
be used to identify the DIP switch settings corresponding to the address you wish to set. If the DIP switches are altered, the power
supply must be cut off and reactivated for the new address to be set on the module.
SimpleProg software is required to program SimpleHome automation devices; this software can be downloaded from the website
pro.comelitgroup.com
Programming must be carried out by connecting the device to the BUS and sending the programming over this.
•
Specifications are subject to change without notice.
•
CAUTION! The module address cannot be changed via SimpleProg.
ART. 20004605 – 2IN / 2OUT 2A BUS MODULE
TECHNICAL CHARACTERISTICS
500 W (with outputs interlocked
electronically from the module)
O1 + O2 = MAX 500 W
20004605 ADDRESS
20004605 PROGRAMMING
24 Vdc ±5%
between 8 and 13 mA
input 1
I1
24 v
V+
input 2
I2
common
C
O1
output 1
O2
output 2
data BUS
D
+
+24 Vdc power supply
-
Power supply negative
On a DIN rail on a dedicated control panel or in a
junction box*
CE
0° to 40°C INDOOR USE
-10° to +70°C
5 to 95% with no condensation
70 g
50 x 50 x 18.5 mm (1 DIN module)
3