Warning
• This Comelit product was designed for use in the creation of security and home automation systems in residential, commercial or industrial settings
and in public buildings or buildings used by the public.
• All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the
indications provided in the manuals / instruction sheets supplied with those products.
• Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
• We advise against running the system wires through the same duct as the power cables (230V or higher).
• Cut off the power supply before carrying out any maintenance procedures.
• To ensure Comelit products are used safely: carefully observe the indications provided in the manuals / instruction sheets and make sure the system
created using Comelit products has not been tampered with / damaged.
• Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in
the manuals / instruction sheets. Any repair work must be carried out: for the products themselves, exclusively by Comelit Group S.p.A., for systems,
by qualified technical personnel.
• Comelit Group S.p.A. does not assume any responsibility for: any usage other than the intended use; non-observance of the indications and warnings
contained in this manual / instruction sheet. Comelit Group S.p.A. nonetheless reserves the right to change the information provided in this manual /
instruction sheet at any time and without prior notice.
ART. 20002710
The 20002710 module, connected to the Comelit home automation system, allows logical functions to
be performed using, as elements of the rule, the events that are sent by the different modules on the home
automation BUS.
The module allows the setting of up to 32 logical rules of 8 elements each, linked by AND - OR operators.
It is possible to link the results of the logical rules in another logical rule, always using the same operators.
TECHNICAL CHARACTERISTICS
Power supply voltage
Consumption
BUS side transmission speed
USB side connector for module
programming
BUS side connector
Approvals
Operating temperature
Storage temperature
Relative air humidity
Indications
Weight
Dimensions
ADDRESSING
The address of the module on the Comelit home automation BUS must be set using the DIP-switches on the
module itself. The table on page 8 can be used to identify the DIP-switch settings corresponding to the address
you wish to set.
• If the DIP-switch is altered, the power supply must be cut off and reactivated for the new address to
be set on the module.
• It is not possible to modify the address of art. 20002710 using SimpleProg.
PROGRAMMING
Programming can be carried out:
• by connecting the device to the PC using the micro USB, which also supplies the necessary power.
• by connecting the device to the BUS and sending the programming over the BUS.
24 VDC ± 5%
10 mA
2,400 bps
Type B micro USB female
connector
terminal block*
CE
0° to 40°C INDOOR USE
-10° to +70°C
5 to 95% with no condensation
• Flashing yellow LED:
data transmission on BUS;
• Steady yellow LED: power supply
negative absent or incorrect
connection of device;
• Red LED: possible collision of
messages on BUS.
70 g
42 x 42 x 18 mm (1 DIN module)
*TERMINAL BLOCK
-
Power supply negative
+
+24 VDC power supply
D
Data BUS
• SimpleProg software is required
to program Comelit home
automation devices; this software
can be downloaded from the
website pro.comelitgroup.com
• Specifications are subject to
change without notice.
3