Top Mount Models Installation

TOP MOUNT WIRING AND ELECTRICAL CONNECTIONS

Do not lift the unit by the refrigerant tubing or other components. These features will not support the unit weight. Injury
and unit damage may occur!
All wiring must comply with local and national codes. Wiring must be performed only by a refrigeration technician or
certified electrician. Failure to follow these guidelines may result in injury!

INSTALLING UNIT TO CEILING PANEL

Lift the unit from its shipping crate using the lift rings located on top of the unit.
Center the evaporator air intake/discharge over the panel opening and lower into position.
To ensure there is no air infiltration into the walk-in, the gasket around the evaporator box must seal around the panel
opening.
Loosen the screws with slotted holes that connect the condensing unit to the evaporator box.
Push down on the evaporator box to ensure the gasket is sealed.
Check to ensure the condensing unit base is level and supported, then retighten the screws.