Advanced Menu - Kolpak A421 Manuel D'installation, De Fonctionnement Et D'entretien

Système de réfrigération à encastrer
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Viewing and changing values in the Basic menu
To access the Basic menu and view and change the Basic parameter values, complete the following steps:
1. On the Main screen, press MENU. The LCD displays OFF, which is the first parameter code screen displayed in the
Basic menu.
2. To scroll through all of the basic parameter codes and display the preferred code, press Down or Up.
3. With the preferred parameter code displayed, press MENU to display the current parameter value for the code.
4. With the current parameter value displayed, press Down or Up to scroll through all of the parameter's usable
values and display the preferred value.
5. With the preferred parameter value displayed, press MENU to save the displayed value and go to the next
parameter code.
6. To exit the Basic menu and go to the Advanced menu, simultaneously press and hold Down or Up for 5 seconds.

Advanced menu

You can use the Advanced menu to change the parameter values in the Basic menu and the parameter values for the
following advanced parameter codes:
1. Temperature Units (Un)
2. Low Temperature Setpoint Stop (LtS)
3. High Temperature Setpoint Stop (HtS)
4. Anti-Short Cycle Delay (ASd)
5. Defrost Cycle Time (dFt)
6. Defrost Interval (dI)
7. Binary Input Mode (bLn)
8. Backlight Brightness Level (bLL)
9. Temperature Setback (tSb)
10. Sensor Offset (So)
11. Sensor Failure Option (SO)
12. Start or Stop Defrost Cycle (SdF)
See Parameter codes and modes of operation for more information about parameter codes, usable parameter values, and default
values.