The timer starts the defrost cycle automatically at the predetermined times.
A setting of two to four defrost cycles per day is typical. For heavier frost loads, additional cycles may be required.
When the defrost cycle begins:
The compressor will stop but the evaporator fan(s) will continue to run.
Air is pulled across the evaporator coil without refrigerant running through the system. The coil temperature to
increases above 32°F/0°C melting the frost and ice.
The system remains in defrost through the duration programmed on the timer. Once the duration is complete,
the compressor activates and refrigerant starts cycling through the system.
The system operates in the refrigeration cycle until the next defrost cycle is initiated by the timer.