Vertical Installation On The Cover; Electric Motor; Electric Motor Reference Standard (Eu) - Rico RIC M 30 S Instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 50

12.4 VERTICAL INSTALLATION ON THE COVER

The units can be installed with the working axis vertical, as follows:
Using vibration dampers fitted directly on the cover (E)
Using a special foot for vertical fixing, available as an accessory (F).
Non-compliance with the unit's intended use can cause serious
injury.
Regularly check the fixing of the unit to the support structure.
Excessive vibration of the unit can seriously damage the machine.
NOTE FOR THE USER
NOTE FOR THE USER
ATTENTION!
ATTENTION!

12.5 ELECTRIC MOTOR

The side channel blowers are equipped with electric motors with specifications: single-phase, two-pole three-phase, continuous duty
(S1), according to efficiency class as per the current regulations.
The motors of RIC MxxS; MxxD; TxxS; TxxD have PTO thermal protectors (standard), PTC on request.
Danger of sudden restarting.
The PTO thermal protector is an normally-closed electromechanical device. Once the tripping temperature is reached, it opens and
stops the electric motor. The electric motor resumes normal operation when the temperature falls below the trip threshold. Take
suitable steps to prevent injury and damage to property in case of sudden restarting.
ATTENTION!
The units are equipped with motors S1 for continuous operation.
A maximum of 6 starts per hour, equally distributed, are permitted. Non-compliance can damage the unit.
For GOR version blowers, comply strictly with the safety measures and instructions given in the
electric motor instruction manual.
12.5.1

ELECTRIC MOTOR REFERENCE STANDARD (EU)

The electric motors that power the machines are CE marked
The wide range three-phase electric motors supplied by RICO that power RIC version blowers ensure correct operation in the
range of voltages specified on the rating plate, which is wider than that provided for by the regulations for standard motors:

Up to 4.0 kW inclusive: 345-415/200-240V 50Hz - 380-480/220-280V 60Hz. IE2 only 230/400V-50Hz
5.5 kW to 15 kW inclusive: 600-720/345-415V 50Hz - 660-830/380-480V 60Hz. IE2 only 400/690V-50Hz

RIC version blowers with electric motors exceeding 15 kW are not wide range, and are not IE2

The electric motors comply with EU regulation 4/2014 and the efficiency class specified in standard IEC 60034-30
 Druckluftanlagenbau GmbH
RIC M30S – M120S
RIC M70RD – M120D
A special foot is available as an accessory for fixing the unit vertically
on the cover. The foot has holes for fixing; use all the holes and
choose the appropriate type of screw.
Vibration dampers are supplied with machines from 70 to 120. On
request, vibration dampers are also available on the other machines.
Avoid the possibility of water stagnation, especially in case of
installation of the unit with vertical axis.
Check the motor rotation direction.
(see par. 5.2 ROTATION DIRECTION)
Tel. +49 ( 0 ) 2151 9931 99 -