2. DESCRIPTION OF THE REPEATER
5
«Learn» button
Radio module
Radio antenna
Backup supercapacitor making it possible for the product to keep on operating for 6 hours in case of main
1
power failure.
«Mode» DIP: Selection of the «Learn» mode:
2
3
«Test» Button: use to test the link between the rerpeater and the transceiver.
«Test» LED.
4
«Learn» Button : use to add remote control units.
5
«Learn» LED.
6
«ON/OFF» switch.
7
- ON: the product keeps operating, powered by the supercapacitor, in case of power failure.
- OFF: the product is not kept operating in case of main power failure.
8
Supercapacitor charging status LED: ON = supercapacitor is charging, OFF = supercapacitor is fully
charged.
3. INSTALLATION
The commissioning of the repeaters must be accomplished progressively, one repeater at a time.
3.1 Chosing of the repeater(s) location
To avoid triggering an alarm during the choice of the location we recommand that the receiver be disconnected
from the external inputs of the Sigma master clock (do not disconnect the power from the receiver). (Refer
to the LoRa Transceiver user manual 608073)
10
«Test» button
3
«Test» LED
4
6
«Learn» LED
power connection
«Mode» DIP
2
1
LoRa Receiver
Keep the
Disconnect the
external inputs
Backup supercapacitor
«ON/OFF» switch
7
Power supply unit
100-240VAC/5VDC
Supercapacitor
8
charging status
100-240VAC power
A
terminal block
EN