GAS CONNECTION
Warning:
The gas installation may only be connected by an authorised local gas
technician.
It is essential to ensure that the gas supply pipes and the connection pipes for
the corresponding measurement systems are the correct diameter.
Check that the gas supply is correctly sealed.
MAXIMAL TERMAL LOAD
Type of gas
Natural gas H G-20 (m³/h)
Butane gas G-30 (kg/h)
Propane gas G-31(kg/h)
The air required for combustion of 2m3 / h per kW of power.
Remarks:
Observe the regulations issued by the local gas company.
Observe the regulations for the installation.
Check that the gas indicated in the section is identical to that supplied.
A pipe of at least Ø 12 x 10 mm should be used for the gas connection to the
appliance, together with a ¾" nut to connect to the oven (Fig. 9 and Fig. 10)
Gas shut-off valve in front of each appliance.
Required
Fluidity
pressure
APG-061
APG-101
(mbar)
20
1,270
29
0,998
37
0,984
26
APG -201
APG -102
1,905
3,809
3,704
1,498
2,995
2,912
1,476
2,951
2,869
APG -202
6,878
5,408
5,329