Stopping The Generator

1. Turn off the power switch of the electric equipment and unplug the
cord from receptacle of the generator.
2. Allow the engine about 3 minutes to cool down without load before
stopping.
3. Push the engine switch to the OFF position.
4. Push the main switch to the OFF position.

OIL SENSOR

The oil sensor detects a drop in oil level in the crankcase and
automatically stops the engine when the oil level drops below a
predetermined level.
When the engine has stopped automatically, turn off the generator,
and check the oil level. Refill engine oil to the upper level as instructed
and restart the engine.
DO NOT remove oil sensor probe when refilling with oil.
Remove oil filler cap on the opposite side of carburetor.