Daikin Rotex GW-30 C22 Instructions D'installation page 86

Masquer les pouces Voir aussi pour Rotex GW-30 C22:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 110
5.10.6 Air supply from the facade and a roof outlet with communal
exhaust system
Unit category: C83
IMPORTANT
• An air supply from the outside wall and a roof outlet with a
combined flue system is allowed.
• The air supply in the facade must be fitted with an inlet grid
(A).
• The combined flue system must be fitted with a traction
extractor hood (B).
• If the combined flue system is situated in the outdoors,
the output pipe must be double-walled or insulated.
The minimum diameters of the communal output system based on vacuum
Number of units
22
2
110
3
130
4
150
5
180
6
200
7
220
8
230
9
240
10
260
11
270
12
280
.
Communal combustible gas outlet
The output of the combustion gas outlet can be made in any location on the sloping
roof surface, providing the outlet in the roof surface has the same orientation as the
air supply in the facade. On a flat roof, the outlet of the combustion gas outlet must be
made in the "free" outlet area.
Fit a condense output.
Note
The communal outlet is certified in combination with the unit.
Flue tube diameter
RKOMBG*AAV1
28
33
130
130
150
150
180
180
200
200
220
220
230
230
250
250
270
270
280
280
290
290
300
300
33

Publicité

Table des Matières
loading

Table des Matières