Kemper MiniFil 65150 Mode D'emploi page 58

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 68
filter and to protect it from flying sparks It is recommended that the pre-separator is
checked and if necessary emptied e.g. on a daily or weekly basis.
WARNING
Severe damage to health of respiratory organs and the respiratory
tract - wear respiratory protection e.g.
KEMPER autoflow XP or a respiratory protection filter mask
of class FFP2 as per EN 149.
Skin contact with welding fumes etc. may lead to skin irritations if
the person is sensitive - wear protective clothing.
• Open the upper clamps (picture 1 item 7) and remove the cover from the
device (picture 1, item 1) anchored to the floor.
• After this, open the two bottom clamp fasteners and remove the separate
housing (Fig 1, Pos. 2). When doing so, ensure that as a little dust as possible
is whirled up, and that the main filter remains on the filter unit.
• Now empty the pre-separator properly following the official regulations. Please
request the relevant waste codes from the local waste disposal service.
• Carry out the first two work steps in reverse order.
As the dust accumulation in the filter increases, its resistance to through-flow
increases and the device suction decreases. As soon as it falls below a minimum
value, the signal horn sounds and the green operating lamp goes out. It is now
necessary to replace the filters in the main and suspended matter filters.
- 58 -
Technical modifications and errors expected.
KEMPER MiniFil Operating manual - EN

Publicité

Table des Matières
loading

Table des Matières