Charging does
not start when
connected to
power socket.
Unpleasant smell
from the shaver
head.
Battery perfor-
mance dropped
significantly.
Shaving perfor-
mance dropped
significantly.
Shaver head is
damp.
CLEAN&CHARGE STATION
Cleaning does
not start when
pressing the
start button.
20
1. Sometimes charging
could start delayed
(e.g. after long stor-
age).
2. Ambient temperature
is out of valid range.
3. Special cord set is not
plugged in properly.
1 Shaver head is cleaned
with water.
2. Cleaning cartridge is in
use for more than
8 weeks.
1. Foil and cutter are
worn which requires
more power for each
shave.
2. Shaver head is regu-
larly cleaned with
water but not lubri-
cated.
1. Foil and cutter are
worn.
2. Shaving system is
clogged.
1. Drying time after auto-
matic cleaning was too
short.
2. Drain of the
Clean&Charge Station
is clogged.
1. Shaver is not placed
properly in the
Clean&Charge Station.
2. Cleaning cartridge
contains not enough
cleaning fluid (display
blinks red).
1. Wait a few minutes, if charging will
start automatically.
2. Recommended ambient temperature
for charging is 5 °C to 35 °C.
3. Special cord set needs to snap into
place.
1. When cleaning the shaver head with
water only use hot water and from time
to time some liquid soap (without
abrasive substances). Remove Foil &
Cutter cassette to let it dry.
2. Change cleaning cartridge at least
every 8 weeks.
1. Renew Foil & Cutter cassette.
2. If the shaver is regularly cleaned with
water, apply a drop of light machine oil
on top of the foil once a week for lubri-
cation.
1. Renew Foil & Cutter cassette.
2. Soak the Foil & Cutter cassette into hot
water with a drop of dish liquid. After-
wards rinse it properly and tap it out.
Once dry apply a drop of light machine
oil on the foil.
1. Clean directly after shaving to allow
enough time for drying.
2. Clean the drain with a wooden tooth-
pick.
1. Insert shaver into the Clean&Charge
Station and push it to the rear side of
the station (contacts of the shaver need
to align with contacts in the station).
2. Insert new cleaning cartridge. Press
start button again.