BATTERY CHARGER

13) TECHNICAL DATA

Input voltage AC
220-240 V AC, 50 / 60 Hz
Output voltage
Nominal: 12 V
Starting current
Less than 25 A
Input current
0.6 A
Efficiency
75%
Charging voltage
14.4 V ±0.25 V or 14.7 V ±0.25 V
Charging current
3.8 A ±10% or 0.8 A ±10%
Back current drain
1 mA
Back current drain is the amount of current drawn by the charger from battery, when the charger is connected to the battery,
without power cord connected. This chargr has extremely low back current drain which corresponds to 0.7 Ah per month
(1mAIhr)
Ripple
Max. 150 mV
Ripple refers to interference of current and voltage. A high current ripple heats up battery and reduces life of battery.
Against a linear charger, which has a currentripple of up to 400%, the charger's current ripple is below 2% (0.15112 V
battery voltage), which is much lower than the max 5% for a sealed acid battery. Equipments connected to the battery
could be damaged by high voltage ripple.
Ambient temperature
-20°C to 50°C, Reduced output power at higher temperature
Type of charger
5 step, fully automatic, switch mode with maintenance charging
Type of batteries
12 V Lead-acid batteries (WET, MF, AGM and GEL)
Battery capacity
1.2 - 120 Ah
Dimensions
172 x 63 x 42 mm
Housing protection
IP65 (Dust and splash proof)
Weight
0.486 kg
Noise level
Less than 50 dB (Tested from a distance of 50 cm)