_CombiPower_BA_DE-IT.book Seite 61 Freitag, 21. Oktober 2011 8:10 20
CombiPower
Input data
Rated input voltage
Input voltage range
Input overvoltage protection
Input undervoltage protection
(programmable)
Idle current consumption
Standby current consumption
Output data
Output voltage (programmable)
Constant output power
Frequency (programmable)
Peak output power
Efficiency
Short circuit protection
Wave form
Protective devices
DC battery connection
AC inverter output
AC output
AC input
Battery protection
EN
CombiPower 2012
CombiPower 2024
12 V g
10.5 – 16 Vg
15 – 16 Vg
10.5 – 11.5 Vg
5 A
1.5 A
CombiPower 2012
CombiPower 2024
200 – 240 Vw ±5%
2000 VA
47 – 63 Hz ±0.01%
2300 VA for up to 3 min
3000 VA pulse power
> 87% at 12 Vg
> 88% at 24 Vg
Yes, Ipk
Pure sine wave,
maximum 3% distortion
CombiPower 2012
CombiPower 2024
Input fuse
Power-regulated inverter
30 A fuse to for AC input
None
30 A fuse to battery charger
Temperature sensor on battery
Technical data
24 V g
21 – 32 Vg
30 – 32 Vg
21 – 23 Vg
2.5 A
0.75 A
61