Connections And Controls - Dometic GROUP WAECO CombiPower 2012 Notice D'utilisation

Onduleur sinusoïdal avec chargeur automatique intégré
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

_CombiPower_BA_DE-IT.book Seite 42 Freitag, 21. Oktober 2011 8:10 20
Technical description
4.2

Connections and controls

No. in
fig. 1,
Designation
page 3
1
POS (+)
2
NEG (–)
3
5A CHARGER/
2.5A CHARGER
4
INV. AC OUTPUT 230 V inverter output
5
AC OUTPUT
6
AC INPUT
7
8
CIRCUIT
BREAKER
9
CHASSIS
GROUND
10
42
Explanation/function
Positive terminal
Negative terminal
5 A/2.5 A charger connection
L: Live conductor
N: Neutral conductor
FG: Earth connection
230 V output
L: Live conductor
N: Neutral conductor
FG: Earth connection
230 V input
L: Live conductor
N: Neutral conductor
FG: Earth connection
Cover
LS: Circuit breaker
The circuit breaker is triggered when there is
excess current or a short circuit.
➤ Eliminate the cause of the fault.
➤ Press the switch to reset the device.
Earth connection
Main switch:
0: Off
I: On
The main switch overrides the remote control set-
tings. When the main switch is in the "0" position,
you cannot switch on the device with the remote
control.