Troubleshooting
Fault
No output voltage, "Inverter"
LED lights up red, display
shows "OLP Shutdown"
No output voltage, "Inverter"
LED lights up red, display
shows "OLP Shutdown"
No output voltage, "Inverter"
LED lights up red, display
shows "UVP Shutdown"
No output voltage, "Inverter"
LED lights up red, display
shows "ENIR TEMP Shut-
down"
No output voltage, "Inverter"
LED lights up red, display
shows "H.S. TEMP Shut-
down"
No output voltage, "Inverter"
LED lights up red, display
shows "BAT. TEMP Shut-
down"
No charging current
No charging current,
"Charger" and "AC Grid"
LEDs are off
No charging current, "Alarm"
LED lights up red, display
shows "UV Alert"
The device constantly
restarts
NOTE
I
If you have detailed questions on the battery specifications,
please contact the battery manufacturer.
58
Cause
Short circuit
Incorrect wiring
Overload
DC overvoltage
DC undervoltage
Overheating
Incorrect frequency
No 230 V power
Overheating
No connection to the battery
CombiPower
Remedy
Check the 230 V cable
Reduce the load (switch off
consumer units)
Switch off the device and on
again
Reduce the battery voltage or
replace the battery
Check the cable
Charge the battery
Check the ventilation grilles
and clean them if necessary
Improve the ventilation
Set up the device somewhere
cooler
Check the configured fre-
quency
Check the 230 V power
supply
Check the wiring
Switch off the consumer
units.
Let the inverter cool down
and ensure better ventilation
Check the battery wiring
EN