Operating manual BDC-122 / BDC-122H
Tightness inspection
Hoses check
Make sure the connecting hoses (Fig. 12) are in a
good condition and correctly fixed.
If the hoses are damaged, broken or badly connected
to the unions, they must be replaced.
When sticky materials are treated, check for possible
clogging along the hose, in the inlet and on the baffle
plate inside the filtering chamber.
To clean, scrape the inlet (2, Fig. 12) from the outside
to remove deposits.
Hopper gasket check
Ensure that the Longopac
(2, Fig. 13). The gasket must be replaced if it is torn,
cut, etc...
Clapet gasket check
Replace the gasket (1, Fig. 13) if it is not tight, or if it
is torn, cut, etc.
bag is tight with the gasket
®
Disposing of the vacuum cleaner
Dispose of the vacuum cleaner in compliance with the
laws in force.
Proper disposal (electric and electronic
■
waste). (Applicable in the European Union
and in countries providing a separate
collection system)
The symbol (Fig. 14), which is present on the product
or in its documentation, indicates that the product
cannot be disposed of together with other domestic
waste at the end of its life cycle.
To prevent damage to the environment or health
caused by improper waste disposal, please separate
this product from other waste and recycle it
responsibly in order to support the sustainable
reutilisation of material resources.
This product cannot be disposed of together with
other commercial waste.
Wiring diagrams
Model (EU)
Item
Type
Q1
4083901850
Q2
4083901850
Model (US)
Item
Type
Q1
4083901814
Q2
4083901814
www.blastrac.ca ‒ custserv@blastrac.com
15/17
Figure 14
Figure 15
Description
Switch 2 pole 20A
Switch 2 pole 20A
Figure 16
Description
Switch 2 pole 20A
Switch 2 pole 20A
Q.ty
1
1
Q.ty
1
GB
1