Operating manual BDC-122 / BDC-122H
Controls and indicators
Main motor Start/Stop indicator and button
1.
You can start/stop the main motor with this
button. If the indicator is lit, the main motor is
ON.
Second motor Start/Stop indicator and
2.
button
You can start/stop the second motor with this
button. If the indicator is lit, the second motor is
ON.
Vacuum gauge
3.
4.
Manual filter shaker lever
Inspections prior to starting
1.
Inlet
Before starting, check that:
The filters are installed;
■
■
The closing band is properly tightened;
■
The vacuum hose and tools have been correctly
fitted into the inlet (1);
■
The Longopac
®
Lock the castor brakes before starting the
vacuum cleaner (2, Fig. 6).
Do not use the device if the filters are faulty.
Starting and stopping the vacuum
cleaner
GB
■
Activate the button/toggle switch (1) to "I"
position to start the first motor (indicator light on
- EU version only).
■
Activate the button/toggle switch (2) to "I"
position to start the second motor (indicator light
on - EU version only).
■
Activate the button/toggle switch (1) to "0"
position to stop the first motor (indicator light off
- EU version only).
■
Activate the button/toggle switch (2) to "0"
position to stop the second motor (indicator light
off - EU version only).
Figure 5
Figure 6
bag (2, Fig. 1) is installed.
WARNING!
WARNING!
Figure 5
Operation
Vacuum gauge (2): green zone (3), red zone (1)
When using the vacuum cleaner:, check the flow
control:
■
when the vacuum cleaner is operating, the
pointer of the vacuum gauge must remain in the
green zone (3) to ensure that the speed of the
intake air does not drop below the safety value of
20 m/sec;
■
If the pointer is in the red zone (1) it means that
the speed of the air in the vacuum hose is less
than 20 m/s, and that the vacuum cleaner is not
operating in optimal conditions. Shake or replace
the filter.
■
during normal operation conditions, close the
vacuum hose, the pointer of the vacuum gauge
must switch from the green zone (3) to the red
zone (1).
WARNING!
When the vacuum cleaner is operating,
always check that the vacuum gauge pointer
remains in the green zone (3).
Consult the "Troubleshooting" chapter if
faults occur.
WARNING!
The air speed in the suction tube must not be
less than 20 m/s.
Condition indicated by the vacuum gauge
pointer in the green zone (3).
WARNING!
All vacuum cleaners can be used only with
hoses whose diameters comply with the
specifications in the "Technical Data" table.
WARNING!
Consult the "Troubleshooting" chapter if
faults occur.
www.blastrac.ca ‒ custserv@blastrac.com
10/17
Figure 7