Using the inverter

11
Using the inverter
➤ Connect your appliance to the inverter.
Switch on at the device
➤ Set the main switch (fig. 2 1, page 4) to the "ON" position.
✓ During the self-test,
the built-in speaker emits tones and the LEDs flash in various colours.
✓ After the self-test, the "Input Level" (fig. 2 4, page 4) and "Status"
(fig. 2 2, page 4) LEDs light up green.
Using an external switch or remote control (accessory).
You can also switch the inverter on and off with a connected external switch
or with a remote control (accessory).
➤ Set the main switch (fig. 2 1, page 4) to "Remote".
✓ If the inverter is switched on via an external switch or the remote control,
the green "Power Status" LED (fig. 2 2, page 4) lights up.
Observe the following when using the device (see also chapter "Trou-
bleshooting" on page 52)
The inverter switches off if:
The battery voltage falls below 10.5 V / 21 V
The battery voltage rises above 15.3 V / 30.6 V
the inverter overheats,
there is an overload (short circuit).
Note
I
If the device is operated at too high a load, there may be repeated
attempts to switch on. As soon as the device is correctly operated
again, the inverter automatically switches on again (recovery func-
tion). If the condition is still not satisfactory after several minutes,
switch off the inverter and inspect the connected consumer device.
Note
I
When operating the inverter at a high load for lengthy periods, it is
advisable to start the engine in order to recharge the vehicle battery.