Set grounding bridge
➤ Unscrew the four fastening screws (fig. 9 2, page 7) from the back side
of the device with the included hexagon socket wrench.
➤ Take off the hood (fig. 9 1, page 7).
➤ Unscrew the grounding screw (fig. 9 4, page 7).
➤ Screw the screw into the pre-drilled hole to the left (fig. 9 3, page 7).
➤ Replace the hood of the device and tighten the screws.
10.6
Install external switch to turn device on and off
Note
I
Connect the external switch to the inverter using a connection ca-
ble with Western telephone jack. Observe the PIN configuration on
the plug for the connection cable.
➤ Cut a connection cable to size according to the following circuit diagrams:
– external switch, voltage supply from the inverter: fig. a, page 9
– Control unit with relay or transistor circuit (TR): fig. b, page 9
– external switch with voltage supply from the battery (BAT) of the vehi-
cle: fig. c, page 9
– external switch with its own voltage supply (DC POWER) e.g. from the
ignition: fig. d, page 9
➤ Connect the external on/off switch with the connection cable on the
remote port (fig. 3 7, page 4).
10.7
Connecting the remote control (accessory)
Caution – risk of damage!
e
Attach the connection to the remote control only in the Remote-
Port II and not in the Remote-Port I. False connections can dam-
age the device!
Ensure that the remote control and inverter require the same input
voltage!
➤ Connect the remote control (accessory) to the Remote Port II (fig. 3 6,
page 4).
Connecting the inverter