CleverLevel
Process conditions for ambient temperatures < 50 °C
Type
Process connection
LBFS-xx1xx.x
G 1/2 A ISO 228-1 BSC
LBFS-xxGxx.x
G 1/2 A ISO 228-1 BSC
with cooling neck
LBFS-xxAxx.x
G 1/2 A DIN 3852-E,
NBR seal
LBFS-xxBxx.x
G 1/2 A DIN 3852-E,
FKM (Viton®) seal
LBFS-xx4xx.x
G1/2 A hygienic
LBFS-xxKxx.x
G1/2 A hygienic, length
82 mm
LBFS-xxLx.x
G1/2 A hygienic,
adjustable connection
LBFS-xx5xx.x
G 1/2 A ISO 228-1
for internal installation
LBFS-xx2xx.x
G 3/4 A ISO 228-1
LBFS-xx3xx.x
G 1 A ISO 228-1
LBFS-xxNxx.x
1/2-14 NPT
LBFS-xxMxx.x
1/2-14 NPT with cooling
neck
LBFS-xx6xx.x
3/4-14 NPT
LBFS-xx7xx.x
M18x1 ISO 965
LBFS-xxExx.x
G 1/2 A DIN 3852-E,
FKM (Viton®) seal,
with cooling neck
1)
Not applicable for mounting with ZPW1-7x1
The temperature specifications apply to a maximum dip depth of the sensor tip into the process area of
20 mm.
14 / 48
Level measurement
®
LBFS
Point level detection
BCID
G07
G07
1)
G51
G51
A03
A03
A03
T10
G10
G11
N02
N02
N03
M11
G51
Operating Instructions
Process
Process
temperature
pressure
continuous
[°C]
[bar]
T
< 50 °C
amb
-40...115
-1...100
-40...150
-1...100
-40...115
-1...100
-40...115
-1...100
-40...115
-1...10
-40...115
-1...100
-40...200
-1...5
-40...85
-1...100
-40...115
-1...100
-40...115
-1...100
-40...115
-1...100
-40...150
-1...100
-40...115
-1...100
-40...115
N/A
-40...150
-1...100
Process
Process
tempera-
pressure
ture
t < 1 h
t < 1 h
[°C]
[bar]
T
< 50 °C
amb
135
-1...100
N/A
N/A
135
-1...100
135
-1...100
135
-1...5
135
-1...100
N/A
N/A
N/A
N/A
135
-1...100
135
-1...100
135
-1...100
N/A
N/A
135
-1...100
N/A
N/A
N/A
N/A
www.baumer.com