Commands
Commands are sent to the SMS module via an SMS message from your mobile telephone.
!
Only lowercase letters
are to be used in commands sent to
the SMS module and no spaces are
to be used.
Command sent to SMS
module
activatenumber
alarmreset
indoorXX
operationdata
Message from
SMS module
Alarm [type]
Confirm with:
[Reset Ok] or
[Not possible]
Outdoor:[xx]
Indoor:[xx] [exp]
Prime flow:[xx]
[exp]
HP:[xx] [exp]
Brine in:[xx]
Brine out:[xx]
Boiler:[xx]
Current:[xx]
El:[xx]
Night
reduction:[xx]
Alarm:[xx]
Function
Activates the SMS function for sending
commands and messages to/from your
mobile telephone number.
HP automatically sends SMS if an alarm
is triggered.
Reset of alarm and confirmation from
product.
Sets the expected indoor temperature
value. The indoor sensor must be
connected for this command to change
the expected indoor temperature value.
The command will otherwise have no
effect.
Example: indoor22
HP responds with a list of temperatures.
NB! Only whole degrees.
Current:[xx] displays max loaded
phase.
Night reduction:[xx] displays yes or no.
Alarm:[xx] displays current alarm, or
'no' when no alarm.