AQUA SALT
Salt chlorine generator
The sample installation diagram below refers to pH, pH/Redox, pH/ClJ chlorine generators. To fasten,
3.2
install and connect the electrolytic cell and control box, please follow the instructions provided for the
standard model.
pH, Rx, ClJ
model
installation
Performing a D24 mm hole
Installing the probe-holder:
Screw the clamping screws evenly to achieve proper fastening. Do not tighten a screw fully
home when the other one is still unscrewed.
Installing a long electrode (120 mm)
Never bend the electrode, which would otherwise be irreparably damaged. The internal part of
the electrode is very fragile!
pH, Redox and Chlorine probes installed in the system must be connected to the control box through the
3.2.1
BNC connectors, as shown below. The label on the right of the connectors indicates their correct use.
pH, Rx, ClJ
probe
connection
ADSP7000648
The probe-holder is installed on a D50 or D63 diameter tube on which a 24 mm diameter hole
has been carried out;
Check the direction of the flow in the tube to insert the injection tube correctly;
The probe-holder must be positioned vertically +- 45°
Conduct a 5 mm pre-hole at the centre of the upper part of the tube;
Expand the hole with the 24mm drill bit supplied in the installation kit, until you introduce the
whole drill bit in the tube;
Deburr the hole by removing the PVC residues
Insert the O-ring on the small injection tube;
Insert the small injection tube on the tube by following the direction of the flow, as indicated by
the arrow on the label;
Position the O-ring in place and hold it there. Apply the upper part of the probe-holder on the
pool tube;
Insert the two screws (if it is a DN63 tube use the two spacers between the upper probe-
holder and the lower collar). Apply the lower part of the probe-holder on the tube and tighten
the nuts on the screws;
It is possible to use a standard electrode (12x120 mm). In this case it is necessary to use all
the parts supplied;
Insert the following in sequence on the body of the probe: the ring nut and then alternate a
spacer and an O-ring as shown forward
Gently insert the electrode on the probe-holder by carrying out small clockwise and
anticlockwise rotations to make the O-rings move down. When all the components are in
place, tighten the ring nut manually.