Performance; Electrical Techniques; Aqua Salt Description; Functioning - aqua SALT Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

AQUA SALT
Salt chlorine generator
1.3.1
Model

Performance

Cell 50
Cell
100
Cell
150
Cell
200
1.3.2
Plate short-circuit and device overheating protection
The system is equipped with a block chlorine production protection that activates in case of a short-circuit on
Electrical
the titanium plates of the electrolytic cell. It also has a protection to save the device from internal overheating.
techniques
Maximum efficiency of the electrolytic cell
The voltage/current control on the plates of the electrolytic cell makes them work always in the highest
efficiency range (current density between 30 and 40mA/sq. cm) even with salt concentrations higher than
those present in the previous table. This guarantees a longer useful life to the electrolytic cell.
Environment operating temperature: 0 ÷ 45 °C
Packaging and transport temperature: -10 ÷ 50 °C
Protection degree: IP65
2 Aqua salt
description
General information: chlorine production takes place only if a stabilized water flow goes through the
2.1
cell. When this occurs, chlorine generated is directly proportional to the current of the cell, whose
electrodes have a constant potential difference. In its turn, the current depends on the concentration of

Functioning

salt in the water, and on the disposition of the electrodes. The electrolytic cell works with a series of
cycles that can last from 15 minutes to 5 hours, at intervals of 15 minutes. Each cycle is composed by
an alternation of ON/OFF phases whose duration is proportional to the set chlorine percentage (Internal
or External timer mode) or proportional to the measured value of chlorine or Redox (proportional
operating mode). Chlorine generation is periodically interrupted to switch the electrode polarization,
which maintains stable performance and prevents limescale from depositing on the surface of the
electrodes. After a programmable polarization time (from 1 to 16 hours), the "Clean" phase will start.
This lasts 10% of the set polarization period. At the end of this phase, before resuming chlorine
generation, the polarity of the electrodes is switched again. The activation can be done as follows:
ADSP7000648
Produce
Pool
d
dimensions
chlorine
(cu. m)
(g/h)
10
50
20
100
30
150
40
200
A salt chlorine generator is a device that produces chlorine to
disinfect pool water through an electrolytic reaction that produces
sodium hypochlorite from an aqueous solution of sodium chloride
(common cooking salt). This way, you will no longer have to buy,
handle or store the common chemicals for pools (sodium
hypochlorite, trichloro, dichloro). You will only have to add a certain
amount of salt, depending on the size of your pool, until reaching a
concentration between 2.00-4.5 g/l ( 2,000-4,500 ppm). After
disinfection, sodium and chlorine will naturally tend to re-join to form
salt. Therefore, the initial dose of sodium chloride is continuously
recycled and reused. Potential loss can be caused by water additions,
reflux or drainage.
External timer: in this case, the electrolytic cell generates chlorine when it is electrically
supplied. It is sufficient to power the device through a timer of the pool, by a timer (time switch)
or directly via the circulation pump and set the desired percentage of production of chlorine and
the cycle time.
rev. 1.4
MAINTENANCE AND INSTRUCTION MANUAL
Current
Salt
Salt level
density
level
(PPM)
(mA/sq.
(g/l)
cm)
3.5 ÷
3500 ÷
31.66 ÷
4.5
4500
44.83
3.5 ÷
3500 ÷
30.96 ÷
4.5
4500
44.46
3.5 ÷
3500 ÷
29.61 ÷
4.5
4500
41.83
3.5 ÷
3500 ÷
32.90 ÷
4.5
4500
40.08
31/07/2017
ENGLISH
Max.
Absorbe
Current
curren
d power
(A)
t
(W)
(A)
1.90 ÷
3
90
2.69
3.75 ÷
6
150
5.33
5.33 ÷
8
200
7.53
7.90 ÷
10
300
9.62
61/264