Manual Feed Activation - Zodiac Régulateur de rH et de pH du ChemLink C1900 Manuel D'installation Et De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

C1900 ORP and pH ChemLink™ Controller
5.3.8
To set the Next Cleaning
Manually set reminder to clean the pH sensor. Enter
Month, then Year for automatic reminder.
Default: JAN 01 (essentially OFF)
PH SETUP: CL 1
FEEDER
FEED TM
DELAY OT
SET POINT
HI ALERT
LOW ALERT
ACID/BASE
NEXT CLN JAN 01
NEXT CAL JAN 01
CAL AT PH
5.3.9
To set the Next Calibration
Manually set reminder to clean the pH sensor. Enter
Month, then Year for automatic reminder.
Default: JAN 01 (essentially OFF)
PH SETUP: CL 1
FEEDER
FEED TM
DELAY OT
SET POINT
HI ALERT
LOW ALERT
ACID/BASE
NEXT CLN JAN 01
NEXT CAL JAN 01
CAL AT PH
5.3.10 To set the Calibration
Calibration for pH reading. Enter the actual pH here to
adjust sensor reading.
Default: 7.5
PH SETUP: CL 1
FEEDER
FEED TM
DELAY OT
SET POINT
HI ALERT
LOW ALERT
ACID/BASE
NEXT CLN JAN 01
NEXT CAL JAN 01
CAL AT PH
|
NONE
CONT
45 MIN
7.5
8.4
6.8
ACID
7.5
NONE
CONT
45 MIN
7.5
8.4
6.8
ACID
7.5
NONE
CONT
45 MIN
7.5
8.4
6.8
ACID
7.5
Installation & Operation Manual
5.4

Manual Feed Activation

5.4.1
To Perform a ORP Manual Feed
At the main ChemLink screen, use the arrow keys to
highlight ORP MANUAL FEED and press SELECT.
At the prompt, highlight OK and press SELECT to start
feed, or GO BACK and press SELECT to cancel and
return to the main ChemLink screen. Pressing BACK/
DONE before pressing SELECT also cancels and
returns to the main ChemLink screen.
CHEMLINK 1
SETUP
ORP 650
PH 7.5
ORP SETUP
PH SETUP
ORP MANUAL FEED
PH MANUAL FEED
LEVEL SWITCH
CHEMLINK 1
SETUP
ORP 650 FEEDING
PH 7.5
ORP SETUP
PH SETUP
ORP MANUAL FEED
PH MANUAL FEED
LEVEL SWITCH
5.4.2
To Perform a Manual pH Feed
At the main ChemLink screen, use the arrow keys to
highlight PH MANUAL FEED and press SELECT. At
the prompt, highlight OK and press SELECT to start
feed, or GO BACK and press SELECT to cancel and
return to the main ChemLink screen. Pressing BACK/
DONE before pressing SELECT also cancels and
returns to the main ChemLink screen.
CHEMLINK 1
SETUP
ORP 650
PH 7.5
ORP SETUP
PH SETUP
ORP MANUAL FEED
PH MANUAL FEED
LEVEL SWITCH
CHEMLINK 1
SETUP
ORP 650
PH 7.5
FEEDING
ORP SETUP
PH SETUP
ORP MANUAL FEED
PH MANUAL FEED
LEVEL SWITCH
ENGLISH
CHEMLINK 1
OK
START ORP
MANUAL FEED?
OK
GO BACK
Feed Confirmation
OK
CHEMLINK 1
OK
START PH
MANUAL FEED?
OK
GO BACK
OK
Feed Confirmation
Page 17