Remedy Of Faults; Troubleshooting Overview - Oase AquaMax Eco Classic 9000 C Notice D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
- EN -
Connecting the controller to the smart phone/tablet
The maximum distance for interference-free communication between the controller and
smartphone/tablet depends on the transmission power of the smartphone/tablet. Brick walls, walls
made of reinforced concrete, large metal objects or bushes and trees can dampen radio waves and
decrease the distance.
Proceed as follows
1.
Download and install the OASE App "Easy Switch" to the
smartphone/tablet.
2.
If you have not already done so, switch on the wireless
connection at the controller.
3.
Activate the Bluetooth feature on the smartphone/tablet.
4.
Start the App "Easy Switch" .
5.
Select your pump from the list.
6.
Enter the authentication code in the smartphone/tablet.
7

Remedy of faults

7.1

Troubleshooting overview

Malfunction
Pump does not start
Pump does not transport fluid
Insufficient delivered quantity
Pump switches off after operating briefly
24
Information
The OASE App is available on iOS (App Store) and Android
(Play Store).
(→ Switching the wireless connection on/off)
After a brief search, a list of available products will appear.
An authentication code will be displayed on the controller for
two minutes.
Upon successful connection, the display will change to the op-
erating instruction page for the pump.
• Now, the pump can be controlled via the smartphone/tablet.
• The LED in the controller display blinks. (→ Controller over-
view)
Cause
No mains voltage
Faulty connection between pump and
controller
Pump not switched on
Filter housing clogged
Excessively soiled water
Pump is set too low
The impeller unit is blocked
Filter housing clogged
Excessive loss in the supply lines
Pump is set too low
Excessively soiled water
The impeller unit is blocked
Pump has run dry.
Remedy
• Check the mains voltage.
• Check supply lines.
Check connection, and if needed recon-
nect
Switch the pump on at the controller
Clean strainer casings
Clean the pump. The pump automati-
cally switches on again once the motor
has cooled down.
Increase the rotation speed of the pump
at the controller
Disconnect the power supply and re-
move obstacle. Then switch the pump
on again.
Clean strainer casings
• Select larger hose diameter
• Adjust stepped hose adapter to hose
diameter
• Reduce hose length to minimum nec-
essary
• Avoid unnecessary connection ele-
ments
Increase the rotation speed of the pump
at the controller
Clean the pump. The pump automati-
cally switches on again once the motor
has cooled down.
Disconnect the power supply and re-
move obstacle. Then switch the pump
on again.
Flood the pump. Fully submerge the
pump for operation in the pond.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aquamax eco classic 12000 cAquamax eco classic 18000 c

Table des Matières