1. Specifications
1.1 Technical data hydro-pro inverter pool heat pumps
Model
Item No.
* Performance at Air 27℃, Water 26℃, Humidity 80%
Heating capacity
Power consumption
C.O.P.
* Performance at Air 15℃, Water 26℃, Humidity 70%
Heating capacity
Power consumption
C.O.P.
* Performance at Air 35℃, Water 27℃, Humidity 40%
Cooling capacity
Power consumption
E.E.R.
Rated water flux
Fan power input
Voltage
Maximum Current
Minimum Fuse
Current
Water in-out
connection
Fan quantity
Ventilation type
Compressor brand
Noise level at 1m
Net dimension
Net weight
Packing dimension
Gross Weight
* Above data are subjects to modification without notice.
Inverter 07
7018545
kW
7-3.6
kW
1.06-0.3
12-6.6
kW
5.1-2.5
kW
1-0.38
6.5-5.1
kW
3.6-1.68
kW
1.25-0.44
3.78-2.88
m
3
/h
2.50
w
5-20
A
4.43
A
12
mm
1
Horizontal
GMCC
dB(A)
40-50
mm
1008*380*577
Kg
54
mm
1095*430*705
Kg
66
Inverter 10
Inverter 13
7018546
7018547
10-2.3
13-2.6
1.52-0.18
1.94-0.2
13-6.6
13-6.7
7.1-1.9
9.6-2
1.4-0.25
1.84-0.27
7.5-5.1
7.5-5.2
5.0-1.21
6.6-1.4
1.75-0.28
2.3-0.31
4.25-2.88
4.49-2.88
3.00
4.00
8-40
8-40
220~240V/50Hz/1PH
6.65
8.57
18
24
50
1
1
Horizontal
Horizontal
GMCC
MITSUBISHI
40-52
40-54
1050*440*709
68
78
1130*470*850
73
83
- 9 -
Inverter 17
Inverter 21
7018548
7018549
17-3.8
20-4
2.54-0.29
2.98-0.3
13-6.7
13-6.7
11.5-3
14-3
2.2-0.37
2.7-0.37
8.2-5.2
8.2-5.1
8.3-2.0
9.7-2.06
2.88-0.42
3.68-0.4
4.73-2.88
5.11-2.64
5.00
6.00
10-50
10-50
11.31
12.98
31
36
1
1
Horizontal
Horizontal
MITSUBISHI
MITSUBISHI
41-56
41-56
1050*450*870
98
108
1140*480*1010
113
123