Jandy Pro Series TruClear Guide D'installation Et Mode D'emploi page 21

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Jandy
Pro Series TruClear
Chlorine Generating System
®
Problem
Chlorine level too high.
(above 7.0 PPM)
No display on LCD
(screen is blank).
Display says "No
Flow".Caused by
insufficient water flow
through the cell.
The display says "Lo
Tmp/Lo Salt".
"Output Fault" appears
on the screen.
Salt level too low.
|
Installation & Operation Manual
Possible Cause
New pool water. Not shocked properly
upon startup.
Clogged or dirty cell.
Chlorine output percentage set too high.
Power pack and cell turned on too long.
No power to unit.
Caused by insufficient water flow through
the cell.
NOTE When the Flow light is on,
the chlorine output will be
turned off.
Dirty filter.
Closed valves.
Pump fails to provide sufficient water
flow.
Salt level is well below 2,500 ppm,
depending on water temperature.
Calcium buildup in the cell
NOTE Salinity readings are taken after 5 minutes and at regular 5 minute intervals. The Salt
warning will turn on when the salt level drops well below 2,500 ppm and it will remain on
until the salt level is raised to 3,000 ppm or slightly above.
Cell life expired.
A combination of low water temperature
(35°-65°F / 2°-18°C) and lower salt
levels (1,500 - 2,000 ppm).
Power supply.
Not enough salt added to pool.
Leak in pool.
ENGLISH
Corrective Action
Super chlorinate the pool.
Remove cell for inspection and clean if
necessary (see Section 6.3).
Decrease chlorine production rate by
pressing the Output button (see Section 5.4)
If chlorine output is set at the lowest setting
and it consistently provides excessive
chlorine levels, decrease operation time as
much as necessary.
Check the connection to the pump timer
(see Section 3.5).
Check if GFCI tripped.
Check and clean the pump and skimmer
baskets.
Clean the filter.
Check and correct all valve alignments.
Check for correct operation of the pump.
Make sure pump is sized properly for
required flow rate.
Maintain a salinity level of 3,000 ppm -
3,500 ppm (see Section 4.6 or contact your
local pool professional).
Clean the Cell
Replace the cell.
Check salt level in pool water. If level is
between 3,000 - 3,500 ppm, no action is
necessary. If salt levels are lower than
2,500 ppm, raise the salinity level to 3,000
- 3,500 ppm (see Section 4.6).
NOTE Salt levels above 4,500 ppm
may cause corrosion damage.
Turn the power off to the power pack and
consult your local pool care professional.
Add salt to pool until salinity returns to
3,000 ppm
(see Section 4.6).
Repair pool.