Safety Cable; Electrical; Led Source; Power - Robert Juliat ZEP 340LF CW Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.1.5

Safety cable

When hung or flown the fixture must be
secured by an additional hanging accessory
(such as a safety bond or cable) of suitable
length.
The combined weight of both the fixture and
the accessories must be considered when
choosing the load-bearing capability of safety
cable or bond.
Safety cables or bonds must be securely
attached to the back of the fixture and be as
short as possible, or rolled up as necessary,
to minimise travel distance should the fixture
be dislodged.
3.2

Electrical

3.2.1

LED source

Never touch or scratch LED surface.
See 5.1.5 LED cleaning procedure if cleaning is necessary.
3.2.2

Power

Voltage
90  264 V
Class 1 product. This luminaire must be earthed.
Must be connected directly to AC power. Do not connect to dimmer power
Automatic power detection
On the same breaker, maximum of: 19 units (230V) / 10 units (110V)
Daisy chain:
Power supply
Frequency
0,8 A / 185 W @ 230V
1,5 A / 185 W @ 120V
47-63 Hz
1,8 A / 185 W @ 90V
Power cable
- 7 -
Input power
Max.2,1 A
Mode veille: 7 W
Maximum of:
19 units (230V)
10 units (110V)
EN
Connectors
Neutrik powerCON TRUE1
Entrée :
ref. NAC3PX (max. 20A)