Continuous drainage
-
Find the drainage opening on the back of the device.
-
Cut out the stopper
-
Put the drainage hose into the opening, put the other end of the hose into a
collecting vessel and pour out the water.
-
Make sure that the hose is securely connected to prevent leakage of water.

MAINTENANCE INSTRUCTION

1. Please always unplug the unit before cleaning.
2. Please note that only the plastic filter may be cleaned.
3. Remove the front cover and carefully remove the filter.
4. If the filter is only slightly dusty, you can quickly and easily clean it with a
vacuum cleaner.
5. Rinse the filter under running water (max. 40 ° C) and dry it with a soft cloth.
6. Clean the appliance with a damp cloth and then wipe with a dry cloth.
7. Do not use chemical solvents (such as benzene, alcohol) or hot water.
8. If the unit will not be used over longer period, please turn the power off, unplug
the power cord and take the unit in a dry, cool and safe place
TROUBLESHOOTING
Problem
Hot air comes from the air
outlet
The unit does not work.
The device does not
dehumidify.
The air does not flow out.
Loud noises during start
up.
Cause
-----------
Is the unit plugged in?
Does the "tank full"
indicator (water tank is full
or misplaced) light up?
Is the air inlet or outlet
blocked?
Is the ambient
temperature or relative
humidity too low?
Is the air filter dirty?
Is the function of the
internal drying activated?
If the device was placed
awry or unstable?
Is the air filter dirty?
Solution
The dehumidifier has no
cooling function; the air
comes out of the
condenser. This is not a
defect.
Plug in the unit.
Empty the water tank and
set it to the correct
position again.
Check the air inlet and
outlet and remove any
obstructions.
Please check the settings.
Clean the air filter as
described in the manual.
Wait until the process is
finished
Place the unit on a stable
flat surface.
Clean the air filter as
described in the manual.