5
Trouble shooting
Thruster does nothing
- Check that the battery main switch is 'ON' .
- Check if the battery voltage is correct (33.6 - 57.6 Volt).
- The battery capacity is reduced because of very low temperatures.
- Check whether the control panel fuse has burnt out.
- Check if one of the main fuses has burnt out.
In all the above cases, the 'POWER' indicator LED is not lit.
- There is an overload condition.
The panel gives a warning signal three times ( . - . . - ) and the LED
will glow red.
As soon as the controller has cooled down enough, the LED will
resume glowing green and the bow thruster can be put back in
service.
Check if it is possible to turn the propeller. A piece of wood or similar
could have been caught between the propeller and the tunnel.
Control panel fuse is burnt out
- Short circuit in the operating circuit; check the wiring.
12
020574.04
6
Technical data
Type
Drive
Type
Voltage
Current
Rated output
No. of revolutions
Rating
Protection
Motors conform to CE (2014/30/EU, EMC - EN55011/EN61000)
Housing
Propeller
Diameter
No. of blades
Profile
Material
Rated thrust
Control circuit
Fuse
Thrust-tunnel
Steel model
dimensions
treatment
Plastic model
dimensions
material
Aluminium model
dimensions
material
Weight
Excl. thrust-tunnel
vetus® Operation manual thruster RIM DRIVE 250 mm
:
RD125
RD160
Brushless Permanent Magnet DC
:
Motor
:
48 V DC
:
130 A
200 A
:
7 kW
11 kW
:
1100 rpm
1250 rpm
:
S1 (100% duty cycle
:
IP65
:
Aluminium
:
246 mm (9 11/16")
:
6
:
asymmetrical
:
polyacetal (Delrin ®)
1250 N
1600 N
:
(125 kgf, 281 lbf )
(160 kgf, 36 lbf )
:
5 A
: O.D. 267 mm, wall thickness 7.1 mm
blasted, coated with: SikaCor Steel
:
Protect. Suitable for all kinds of
protection systems.
: O.D. 264 mm, wall thickness 7 mm
:
glass fibre reinforced polyester
: O.D. 264 mm, wall thickness 7 mm
aluminium, 6061 or 6062
:
(AlMg1SiCu)
:
36 kg (80 lbs)
)