INSPECTING AND CLEANING THE PUMP CHECK VALVE
Remove the five base plate
to these bolts, lay the unit on its back.
NOTICE: Do not place unit on its front, as this might
cause any residual water to drip into sensitive electronic
components.
Remove the front cover.
Stand the unit upright and remove the front cover.
Now remove the four rear panel
Tip the top of the rear panel away from the unit and lay
it flat in front of the unit. It is not necessary to disconnect
the wire harness from the rear panel or from the electrical
box.