When adjusting the floating switch, make sure that the floating
switch does not touch the bottom before the equipment is swit-
ched off. Important! Risk of dry running.
Manual operation:
Mount the fl oat switch as illustrated in Figure 3 so that the device
runs continuously. In this mode the equipment may be used only
under supervision to avoid dry running. The equipment must be swit-
ched off (pull out the power plug) as soon as no more water is emit-
ted from the discharge line.
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged, it must be replaced
by the manufacturer or its after-sales service or similarly trained per-
sonnel to avoid danger.
8. Cleaning, maintenance and ordering of spare parts
GB
Danger!
•
Unplug the power plug prior to any maintenance work.
•
For mobile applications, the equipment should be cleaned with
clear water after every usage.
•
For stationary installation, it is recommended that you check the
floating switch for proper operation every three months.
•
Use a water jet to remove any lint or fibrous particles that may
have become trapped in the housing.
•
Remove sludge from the shaft bottom and clean the shaft walls
every 3 months.
•
Use clear water to remove deposits from the floating switch.