READ AND SAVE THESE INSTRUCTIONS
The Installer must leave these instructions with the homeowner.
The homeowner must keep these instructions for future reference and for local electrical inspec-
tors' use.
READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD
WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: Never leave surface
units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite.
Heat oils slowly on low or medium setting. Always turn hood ON when cooking at high heat or
when cooking flaming foods. Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan or filter. Use proper pan size. Always use cookware appropriate for the size
of the surface element.
WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE
TOP GREASE FIRE, OBSERVE THE FOLLOWING: SMOTHER FLAMES with a close-fitting lid,
cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the
flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT. NEVER
PICK UP A FLAMING PAN - You may be burned. DO NOT USE WATER, including wet dishcloths
or towels - a violent steam explosion will result. Use an extinguisher ONLY if: 1. You know you
have a Class ABC extinguisher, and you already know how to operate it. 2. The fire is small and
contained in the area where it started. 3. The fire department is being called. 4. You can fight the
fire with your back to an exit.
ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE
SEALED.
This rangehood requires at least 24" of clearance between the bottom of the rangehood and the
cooking surface or countertop. This minimum clearance may be higher depending on local building
code. For example, for gas ranges, a minimum of 30" may be required. The maximum depth of
overhead cabinets is 13". Overhead cabinets on both sides of this unit must be a minimum of 18"
above the cooking surface or countertop. Consult the cooktop or range installation instructions
given by the manufacturer before making any cutouts. MOBILE HOME INSTALLATION. The
installation of this rangehood must conform to the Manufactured Home Construction and Safety
Standards, Title 24 CFR, Part 3280 (formerly Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD, Part 280). Four wire power supply must be used and the appliance wiring
must be revised. See Electrical Requirements.
Determine which venting method is best for your application. Ductwork can extend either through
the wall or the roof. The length of the ductwork and the number of elbows should be kept to a
minimum to provide efficient performance. The size of the ductwork should be uniform. Do not
install two elbows together. Use duct tape to seal all joints in the ductwork system. Use caulking
to seal exterior wall or floor opening around the cap.
Flexible ductwork is not recommended. Flexible ductwork creates back pressure and air
turbulence that greatly reduces performance.
Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts.
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a
supporting frame must be constructed
WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.