Kuppersbusch KD 6500.1 Mode D'emploi page 10

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Active carbon filter
• Operation
The activated charcoal filter is only fitted in recirculation type hoods. It will retain odours
until it becomes saturated. It cannot be washed or regenerated, and must be replaced
when the Filters LED starts, or at least once every 4 months of use. Attention:in
recirculation type hoods the T2 Motor LED may start to flash as well as the Speed + T4
LED. This indicates that as well as replacing the activated charcoal filter, it is also necessary
to perform maintenance operations on the metal grease filters.
• Replacing
Remove the grease filters (fig.10) and take out the activated charcoal filter from its housing,
turning the lugs provided (fig. 11). Insert the new activated charcoal filter and replace the
metal grease filters.
• Enabling the alarm signal
In recirculation type hoods the saturated filters alarm must be enabled as indicated below:
- Turn off the lights and the suction motor;
- Press and hold the T4 button for at least 10 seconds, until the LEDs start to flash. Note
the number of flashes:
- 2 flashes of the LED Activated charcoal filter saturation alarm ENABLED.
- 1 flash of the LED Activated charcoal filter saturation alarm DISABLED;
• Resetting the alarm signal
To turn the alarm signal off, proceed as follows:
- Press the T4 button for at least 3 seconds, until the LEDs flash in confirmation. In any
case the saturated filters alarm will only come into operation when the suction motor is
turned on. WARNING: always comply with the maintenance and replacement times
indicated, in order to avoid a possible risk of fire when the filters are saturated
with grease.
Lighting
• Before attemping to replace the lamps, make sure that the light switch is turned off.
• It consists of 2 20 W-halogen spotlights (60 cm model) and 3 20 W-halogen spotlights
(90 cm model).
• Replacement (fig.12)
Remove the two screws that lock the metal ring, take the spotlight out of its holder by
pulling slightly. When replacing, make sure that both pins are well inserted in the holder
seat.
Cleaning
When cleaning the hood:
- Never use a wet cloth or sponge, or running water.
- Never use thinners or products containing alcohol, as they might damage the paintwork.
- Never use abrasive cleaning materials, in particular when cleaning stainless steel surfaces.
It is recommended to use a damp cloth and mild liquid household cleaner.