5 - Undo the screws (G) to remove the lid (H).
6 - Connect the circuit-breaker (A) to the terminal
board (L) of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual.
Use a cable with at least H05RN-F characteris-
tics.
7 - Tighten the cable gland (M).
Important
When connecting, take care over the con-
nection of the neutral and earth wires; if
they are not connected correctly, the burn-
er does not light.
8 - Replace the lid (H), the electrical equipment
box (F) and the control panel (D) on completion
of the operation.
CONVERSION OF GAS SUPPLY
The constructor has tested the appliance with
its own mains gas, identified by the sticker ap-
plied to the nameplate.
If the type of gas to be connected is different from
that used for testing, proceed as follows.
1 - Turn off the gas supply tap (A).
2 - Change the top burner nozzles (see page 23).
IT
3 - Change the oven burner nozzle (see page 23).
4 - Change the top burner pilot light nozzles (see
GB
page 24).
5 - Change the oven burner pilot light nozzle (see
page 24).
DE
6 - If necessary, change the oven burner bushing
see page 24)
FR
7 - Adjust the minimum setting on the gas control
valves of the hob burners (see page 19) and the
ES
oven burner (see page 20).
8 - Remove the sticker from the nameplate and ap-
ply the new one to identify the gas being used.
Important
On completion of the operation, make sure
that there are no gas leaks or malfunctions.
English
G
M
A
- 18 -
G
H
L
IDM-39614603700.tif
IDM-3960200250.tif
IDM-39614601700.tif
IDM-3960200250.tif