Settings And Adjustments - Sit 820 NOVA Instructions D'utilisation Et D'installation

Masquer les pouces Voir aussi pour 820 NOVA:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
9956820-02_MI_820 NOVA_A4
mV versions

SETTINGS AND ADJUSTMENTS

All adjustments must be made on the basis of the specific characteristics of the appliance.
Check inlet and outlet pressure using the pressure test points
points with the provided screws. Recommended torque: 2.5 Nm.
Outlet pressure adjustment
Remove the protective plug (A). Turn the adjustment screw (B) clockwise to increase outlet pressure. After setting, fit
the plug (A) flush.
Overriding the pressure regulator
Replace the plug (A), the adjustment screw (B) and the spring (C) with the accessory (D), code 0.907.037. Torque:
1Nm.
Adjustment of gas flow to the pilot burner
Turn the screw
Overriding the pilot flow adjustment function
Screw the setting screw
Changing the gas family or group
Check that the appliance is suitable for operation with the gas family or group in question. Following the instructions
given above, adjust the outlet pressure to values given in the appliance's instruction book. With third family gases:
override the pressure regulator and gas flow adjustment to the pilot burner.
IMPORTANT: At the end of all setting and adjustment operations, check gas seals and the efficiency of the
appliance. In particular, it is necessary to check that at the minimum (versions with manual gas flow adjustment) and
at maximum outlet pressure flame lift or light back are impossible. After carrying out all adjustments, fit the provided
seals and/or block the setting screws with paint.
DESCRIPTION OF THE VALVE
¿
Control knob
¡
Adjustment knob (versions with manual
gas flow adjustment)
¬
Pilot gas restrictor
Thermocouple connection
ƒ
Mounting for piezo support
Inlet pressure test point
Outlet pressure test point
«
Automatic shut-off valve
ƒ
8
27-10-2003
16:38
Pagina 8
Pilot burner
E
A
¬
clockwise to reduce flow.
¬
in flush and then back off two complete turns. Then seal the setting.
¿
¡ ¬ √
E
A
≈ ∆
«
2
6
room thermostat
10 12
and
provided. After testing, carefully seal test
»
Pilot outlet
...
Main gas outlet
˛
Holes (M5) for fixing flange
¢
Valve supplementary
fixing point
£
Alternative thermocouple connection
§
Magnet unit
Connection to the combustion
chamber
...
˛
£
§
TP = millivolt generator
TH = thermostat
TP TH
TP
TH
»
¢

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

820 nova mv

Table des Matières