3.4.5 Terminal Locations.
Dimension
Terminal Position
A*
Directly below an opening, air brick, opening window etc.
B
Above an opening, air brick, opening window etc.
C
Adjacent to an opening, air brick, opening window etc.
D
Below gutters, soil pipes or drain pipes
E
Below eaves
F
Below balconies of car port roof
G
From a vertical drain pipe or soil pipe
H
From an internal or external corner
I
Above ground roof or balcony level
J
From a surface facing the terminal
K
From a terminal facing the terminal
L
From an opening in the car port (e.g. door , window into the dwelling)
M
Vertically from a terminal on the same wall
N
Horizontally from a terminal on the same wall
P
From a vertical structure on the roof
Q
Above intersection with roof
* I addition, the terminal should not be nearer than 300mm to an opening in the building structure
formed for the purpose of accommodating a built in element such as a window frame.
11
Installation instructions
Distance
(mm)
600
300
400
300
300
600
300
600
300
600
600
1200
1500
300
600
150