ELECTRICAL

To avoid dangerous or fatal electrical shock, turn
OFF power to motor before working on electrical
connections.
Ground Fault Circuit Interrupter (GFCI) tripping
indicates an electrical problem. If GFCI trips and
will not reset, have a qualified electrician inspect and
repair electrical system.
Exactly match supply voltage to nameplate voltage!
Incorrect voltage can cause fire or seriously damage
motor and voids warranty. If in doubt consult a licensed
electrician.
Plug cord of pump directly into a GFCI protected
receptacle.
Voltage:
Voltage at motor must be not more than 10% above or
below motor nameplate rated voltage or motor may over-
heat, causing overload tripping and reduced component
life. If voltage is less than 90% or more than 110% of rated
voltage when motor is running at full load, consult power
company.
Wiring:
Do not alter cord or plug on cord-connected units. Plug in
to a GFCI protected, grounded outlet only. If plug and out-
let do not match, consult a licensed electrician.
Table I, gives correct circuit breaker sizes for the pump
alone. If other lights or appliances are also on the same cir-
cuit, be sure to add their amp loads to pump amp load
before figuring circuit breaker sizes. (If unsure how to do
this or if this is confusing, consult a licensed electrician.)
Values given in table below are for PUMP MOTOR ONLY. If additional accessories are installed on pump
motor circuit (heater, blower, etc.), include their amperage draw when figuring wire and circuit breaker sizes.
TABLE I - RECOMMENDED FUSING DATA
Model Number
1-Speed
ABG4C, ABG4C7
ABG4D, ABG4DL, ABG4D7, ABG4D7L
ABGS4D, ABGS4D7
ABG4DC, ABG4D7C
ABG4E, ABG4EL, ABG4E7L, ABG4E7
ABGS4E, ABGS4E7
ABG4EC, ABG4E7C
ABG4F, ABG4F7
ABGS4FC, ABGS4F7C
ABGS4F, ABGS4F7
2-Speed
ABG4YD, ABGS4YE7
ABG4YE, ABG4YE7, ABGS4YF7
ABG4YF, ABG4YF7, ABGS4YG7
*Time delay fuses are recommended instead of standard fuses in any motor circuit.
Use the load circuit breaker as the master on-off switch.
Install a Ground Fault Circuit Interrupter (GFCI) in circuit;
it will sense a short-circuit to ground and disconnect
power before it becomes dangerous to pool users. For size
of GFCI required and test procedures for GFCI, see manu-
facturer's instruction.
In case of power outage, check GFCI for tripping (which
will prevent normal pump operation). Reset if necessary.
NOTICE: If you do not use conduit when wiring motor, be
sure to seal wire opening on end of motor to prevent dirt,
bugs, etc., from entering.
death. Plug pump into a grounded power supply. Do not alter
cord or plug.
NOTICE: Determine circuit breaker rating from Table I.
Determine correct outlet required from illustration below.
FIGURE 2 - Plug Configurations
Branch Fuse Rating Amps*
15
15
15
15
15
15
15
20
15
15
15
15
25
4
Hazardous voltage. Can shock, burn, or cause
"ABG" Models with -2A2, -2A4, and -3A4 suffix
use 15-amp straight outlet.
"ABG" Models with -2A1 suffix use 20-amp twist-lock outlet.
Max Load Amps
8.0
9.0
8.0
9.4
12.0
9.0
11.9
16.0
11.9
12.0
9.0/2.7
11.7/3.39
16.6/3.6
Voltage/Hz/Phase
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1