INSTALLATION
4. IF THE HOOD IS TO BE "BACK VENTED", PROCEED DIRECTLY TO STEP 5.
Consult the connection diagrams (following) for further details on exhaust outlet placement.
Method 1:
Install the duct(s) from the outside of the home down to the location of the exhaust
outlet(s) on the top of the hood or to the transition (if applicable).
If a transition is used, install duct down to the location of the transition outlet plus 1"
[2.5 cm]. This will allow the transition to engage 1" [2.5 cm] inside of duct.
Method 2:
Install the duct(s) from the outside of the home to the ceiling over the exhaust
outlet(s) on the hood. The end of the duct(s) should extend 1" [2.5 cm] below the
ceiling.
Use foil HVAC tape (not grey cloth duct tape) to seal all joints. See "Vent Accessories" on
page 19 for a listing of available Hestan ducting materials.
TRANSITION HEIGHTS:
Single and Dual Blower (WM1L + WM2L = 900 CFM): 6" round duct will connect directly to
the top of the hood; 8" round will connect directly to the top of the hood. If using
the optional multi-blower transition (AKVT6810, sold seperately), a 10" round duct
connects to it 17-1/2" above top of hood. See "VENT ACCESSORIES" on page 19
for details.
Two Dual Blowers (Two WM2Ls = 1200 CFM):
Two 8" round ducts connect directly to the top of the hood. If using the optional
multi-blower transition (AKVT8812, sold seperately), a 12" round duct connects to it
16-1/2" above top of hood. See "VENT ACCESSORIES" on page 19 for details.
CONNECTION DIAGRAMS
5-1/2"
[14 cm]
(Wall Side)
Electrical (2)
WM2L Dual + WM1L Single Blower (900 CFM)
5-1/2"
[14 cm]
1-3/4"
[4.4 cm]
Two WM2L Dual Blowers (1200 CFM)
(CONT.)
Connection Diagram (42" width)
7-5/16"
[18.6 cm]
Motor
Cooling
Vent (3)
8" Round
Connection Diagram (48-54" widths)
11"
[29.9 cm]
Motor
Cooling
Vent (4)
8" [20.3 cm]
Round
7-5/16"
[18.6 cm]
5-1/4"
[13.3 cm]
Centerline
of hood
(Top View)
11"
[29.9 cm]
Electrical (2
)
Centerline
of Hood
(Top view)
©2019 Hestan Commercial Corporation
1-7/8"
[4.8 cm]
1-3/4"
[4.4 cm]
6" [15.2 cm]
Round
(Wall Side)
5-1/4"
[13.3 cm]
8" [20.3 cm]
Round
13