Parker UHPZN2-1000 Mode D'emploi page 24

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Problem
Reduced purity.
Pressure Sensor Fault
Generator stops running.
20
Indication
Downstream monitoring
P R E S S U R E S E N S O R
F A U L T
F A I L U R E T O
S W I T C H
Possible Cause
Leaking outlet pipe-work.
Unsuitable pipe-work used on outlet.
Generator recently brought online.
Inlet air supply IS08573.1
2010 air quality class 1.-.1.
(non compressor units only)
Faulty pressure sensor
The Heater / Catalyst is faulty.
The generator is not cycling correctly.
Action Required
Check pipe-work & rectify.
Check pipe-work and replace.
Check & allow at least 6-hours for purity to be
achieved.
Check inlet air quality & rectify.
Contact Parker for advice.
Contact Parker for advice.
Press and hold the
and
seconds to reset the generator.
Note. This operation can only be performed 3
times, after which the display will lock. If this
occurs contact Parker for advice.
keys for 5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Uhpzn2-3000Uhpzn2-1000cUhpzn2-3000c

Table des Matières