4. Operation
<Auto operation (dual set point) mode>
When the operation mode is set to the Auto (dual set point)
mode, two preset temperatures (one each for cooling and
heating) can be set. Depending on the room temperature,
indoor unit will automatically operate in either the Cool or
Heat mode and keep the room temperature within the pre-
set range.
The graph below shows the operation pattern of indoor unit
operated in the Auto (dual set point) mode.
After 5
seconds

4.3. Selecting a fan speed (FAN)

Press the
button 4.
• Each time the button is pressed, the setting changes.
Auto
• The available fan speeds depend on the model of the indoor unit.
Note:
In the following cases, the actual fan speed generated by the unit may be different from the speed shown on the remote controller display.
• The unit is performing the warming-up operation or the defrosting operation.
• Immediately after starting the heating operation (while the system is waiting for the mode change to take effect).
• In the heating mode, the room temperature is higher than the temperature setting.
• In the cooling mode, the room temperature is lower than the temperature setting.
• The unit is in the dry mode.
Preset temp.
(COOL)
Preset temp.
(HEAT)

4.2. Selecting a temperature

To decrease the temperature, press the
To increase the temperature, press the
• Each time the button is pressed, the set temperature
changes 0.5°C (1°F).
• The setting ranges for the temperature are as follows.
Cool/Dry
19–30°C
67–87°F
When using the AUTO (dual set point) mode
• The set temperature for the current operation mode,
cooling or heating, is displayed.
• When the
perature blinks and the setting screen is displayed.
Setting screen
To change the upper limit (cooling) for the set temperature
range, press the
To change the lower limit (heating) for the set temperature
range, press the
• In the setting screen, press the
the blinking display between the upper limit (cooling) and
lower limit (heating).
• Press the
change the blinking set temperature.
• If no operations are performed for 5 seconds, the display
returns to the previous screen.
* The difference between the upper limit (cooling) and lower
limit (heating) cannot be set to less than 2°C (4°F).
* The AUTO (dual set point) mode cannot be used depending
on the models of the connected indoor and outdoor units.
Operation pattern during Auto (dual set point) mode
The room temperature
changes corresponding
to the change in the
outside temperature.
HEAT
COOL
Heat
Auto
17–28°C
19–28°C
63–83°F
67–83°F
or
button 3 is pressed, the set tem-
button 3.
button 3.
or
button 3 in the setting screen to
Room
temperature
HEAT
COOL
button 3.
button 3.
Fan
Not settable
button 2 to switch
9